Commissioning
Commissioning is the final pre-handover stage testing every installed system. What gets commissioned, who signs, and the paperwork that lands in the build pack.
Ask Chalkline about this →Commissioning is the final pre-handover stage of a residential build where every installed service is energised, tested under operating conditions, balanced, and signed off. It happens after second-fix and before practical completion. A site that has not been fully commissioned cannot be lawfully occupied; commissioning paperwork is part of the evidence the certifier wants before issuing the Occupation Certificate.
What typically gets commissioned on a Class 1 or Class 2 residential job:
- Electrical: switchboard energisation, RCD trip tests, circuit identification, smoke alarm interconnection. The licensed electrician issues a Certificate of Compliance Electrical Work (or state equivalent).
- Gas: pressure test, appliance light-up, leak check. The licensed gasfitter issues a Gas Certificate of Compliance under AS/NZS 5601.1.
- Plumbing and drainage: hydraulic pressure test, drainage test, fixture flow and pressure check per AS 3500. The licensed plumber issues a Certificate of Compliance.
- Hot water unit (HWU): filling, energising, temperature set per the AS 3500 / TMV requirements.
- HVAC (ducted heating, cooling, ventilation): airflow balancing across registers, refrigerant charge check, condensate drainage check. The HVAC contractor issues a test-and-balance (T&B) report.
- Solar PV and battery: inverter commissioning, isolator labelling, network connection sign-off.
- Fire detection and emergency lighting (mainly Class 2): alarm test, battery backup test, AS 1670 / AS 2293 sign-off where applicable.
- Swimming pool, spa, bore pump: filling, pump priming, chlorinator commissioning.
Paperwork in the build pack. Each commissioning step ends with a written certificate from the licensed trade. The builder collates these into the handover pack along with appliance manuals, warranty cards, and as-built drawings. Missing certificates delay the certifier and delay handover.
Common builder mistake. Booking the final certifier inspection before HVAC balancing or solar PV grid sign-off has completed. Those two items typically have the longest lead times; book them as early as the schedule allows.
Also known as: system commissioning, T&B, test and balance.
Category: Pre-handover / completion / certificates.